Table of power configuration and melting rate using CAS type power supply

2017-11-28

  Iron melting(1450ºC),Type CAS power supply

Furnace capacity t

1

1.5

2

3

4

5

7

10

12

15

20

25

Power kw

600

900

1200

1800

2500

3000

4000

6000

6600

8200

12M

14M

Frequency Hz

500

500

500

500

300

300

300

300

300

250

250

250

melting rate t/h

1

1.6

2.1

3.3

4.6

5.2

7.5

11.4

12.6

16

23.5

27.4

Power consumption kwh/t

540

535

535

520

520

520

510

500

500

490

485

485

 
  At Steel melting temperature 1650ºC,the melting rate will be 89%and the power consumption will be 110%of data listed in above table.
 
  Copper melting(1200ºC),Type CAS power supply
 

Furnace capacity t

1

1.5

2

3

5

7

10

12

15

20

25

30

Power kw

500

800

1000

1500

2500

3200

4500

6000

6600

9000

11M

13.2M 

Frequency Hz

500

500

500

500

250

250

200

200

200

200

200

200 

melting rate t/h

1

1.7

2.2

3.5

5.9

7.6

10.8

14.4

16.1

22

27.3

32.8 

Power consumption kwh/t

440

430

425

410

400

400

395

395

390

390

380 

380 

  Aluminum melting(700ºC),Type CAS power supply

Furnace capacity t

0.4

0.6

0.8

1

1.2

1.6

2

3

5

7

10

Power kw

250

400

500

700

800

1000

1250

1800

3000

4000

6000

Frequency Hz

500

500

500

500

500

300

300

300

300

250

250

melting rate t/h

0.42

0.67

0.85

1.2

1.4

1.73

2.24

3.22

5.53

7.4

11

Power consumption kwh/t

570

570

560

560

550

550

530

530

515

515

515

 
  The allowing max.working temperature depends upon the selected lining mass;
  The melting rate and power consumption should be measured at the third heats when the lining to be in thermal stable status and 30%of remain liquid in crucible.To take continuous measuring in three heats and takes its average value as the final data.

melting,temperature